This Reduction Oxidation Media is Tested and Certified by NSF International against NSF/ANSI Standard 42 for material requirements only.
Chlorine Removal Test
Lab Test Results for Bacteria from Clack Corporation
KDF® 55 Process Media Tested in Lab Shows 90% Chlorine Removal in Water Filter Cartridges
Lab Test Results from Clack Corporation
KDF Fluid Treatment, Inc.
Attn: Mr. Don Heskett
PO Box 277
Constantine, MI 49042

Dear Don:
You may be interested in some of the results we have obtained using your KDF® 55D media in our water filter cartridges. The cartridges normally contain 45 cu in (740 cu cms) of granular activated carbon. In testing we maintain a flow rate of 1 gpm (3.8 L/min.) and a free chlorine feed of 2 mg/L.
Cartridges with standard grade carbon have a capacity of about 4,000 gallons to 90% removal and 8,000 gallons to 75% removal. If premium carbon is used, typical capacities are 12,000 gallons to 90% and 20,000 gallons to 75%.
When 1-1/2 lb (0.68 Kg) of KDF-55D was combined with Premium carbon, capacities increased to 30,000 gallons at 90% and 54,540 gallons at 75%. When an entire cartridge was filled with KDF, the test was carried out to 82,640 gallons (313,000L) before the test was terminated because of pressure loss. The KDF was still removing 94% of the chlorine!
I have included a graph with typical tests plotted.
Sincerely,
Mel Hemp
Research & Development
Clack Corporation
Windsor, Wisconsin
Chlorine Removal Rate Table



This Reduction Oxidation Media is Tested and Certified by NSF International against NSF/ANSI Standard 61 for material requirements only.

Water Quality Association
Member