This Reduction Oxidation Media is Tested and Certified by NSF International against NSF/ANSI Standard 42 for material requirements only.
Bacteria Lab Test Results One
KDF Lab Test Results from Biological Research Solutions
Lab Test Results Show How KDF Process Media Work in Water Treatment Processing for Bacteria Removal
KDF Lab Test Results from Biological Research Solutions
Laboratory Service Performed:
Analysis of the mode of action of KDF versus Pseudomonas fluorescens.

Sample # | Bacterial Injector | KDF Column | Description of Purpose | |
---|---|---|---|---|
1 |
Off |
Off |
Control: |
Measure survival of Ps. fluorescens in water that has passed through the system KDF off by inoculating after collection. |
2 |
Off |
On |
KDF Elution: |
Measure survival in water that has passed through KDF by inoculating after collection. |
3 |
On |
Off |
Control: |
Measure survival of Ps. fluorescens that have been injected into the system with KDF off. |
4 |
On |
On |
KDF Contact: |
Measure survival of Ps. fluorescens that have come in direct contact with KDF. |
All water used for testing was deionized and injected with AOAC synthetic hard water to a final concentration of 100 ppm and a pH 7.0 +/-.2
Following collection, the samples were surface plated on Plate Count Agar within 2 to 3 minutes of collection and again after incubation at room temperature for 3 hours.
The same inoculums of Pseudomonas fluorescens was used for injection in to Samples 3 and 4 or for addition to Samples 1 and 2 (added after collection of the water).
Experiment # (Date) | Sample #* | Time 0 | Time 3 hours |
---|---|---|---|
I: 7-18-90 |
1 |
900 |
740 |
? |
2 |
810 |
650 |
? |
3 |
440 |
570 |
? |
4 |
4 |
0 |
II: 7-19-00 |
1 |
1800 |
1600 |
? |
2 |
1800 |
30 |
? |
3 |
2100 |
1900 |
? |
4 |
350 |
33 |
III: 7-21-90 |
1 |
580 |
460 |
? |
2 |
580 |
31 |
? |
3 |
650 |
330 |
? |
4 |
390 |
0 |
IV: 7-23-90 |
1 |
740 |
630 |
? |
2 |
740 |
180 |
? |
3 |
770 |
470 |
? |
4 |
360 |
42 |
Average: |
1 |
1000 |
830 |
? |
2 |
30 |
220 |
? |
3 |
990 |
820 |
? |
4 |
280 |
19 |
* Sample numbers are described in Table 1.


This Reduction Oxidation Media is Tested and Certified by NSF International against NSF/ANSI Standard 61 for material requirements only.

Water Quality Association
Member